H Isolation 30KW High Velocity Permanent Magnet Servo AC Motor
Solution Feature
1.Ideal for the 12000rpm substantial speed
two.Substantial electrical power & high torque
3.Higher effectiveness
4.Small dimension
five.Minimal sounds low vibration
6.Patented cooling composition
7.Effortless upkeep and prolonged daily life time
eight.Tough, dependable
Requirements
Product kind: SRPM180M8O30
Voltage: 380V AC
Rated Electrical power: 30KW
Rate Torque : 23.eight N.m
Working pace: 12000rpm
Isolation: H
Drinking water/dust Evidence: IP54
Pole Variety: eight
Cooling Technique: Oil
Application
Higher-velocity Compressors,Followers,Pumps
Other motors you will be interested in
Motor kind | Voltage (V AC) |
Rated energy (kW) |
Rated torque (N.m) | Rated pace (rpm) |
Effectiveness (%) |
Provider Aspect | Insulation | Ingress safety | Pole Variety | Bodyweight (kg) |
Cooling Method | Position Sign | Set up Approach |
SRPM151M8XW11 | 380 | 11 | 11 | 9600 | 96 | S1 | H/F | IP67 | eight | ten | Oil circulation | Resolver | B35 |
SRPM205M8XO45 | 380 | 45 | 36 | 12000 | 96.3 | S1 | H/F | IP67 | 8 | 35 | Oil circulation | Resolver | B35 |
SRPM205M8XO55 | 380 | fifty five | forty three.8 | 12000 | 96.3 | S1 | H/F | IP67 | 8 | 38 | Oil circulation | Resolver | B35 |
SRPM205M8XO75 | 380 | 75 | 59.seven | 12000 | 96.five | S1 | H/F | IP67 | 8 | 43 | Oil circulation | Resolver | B35 |
SRPM205M8XO90 | 380 | ninety | 71.six | 12000 | 96.5 | S1 | H/F | IP67 | eight | forty seven | Oil circulation | Resolver | B35 |
SRPM205M8XO110 | 380 | a hundred and ten | 87.six | 12000 | ninety six.five | S1 | H/F | IP67 | 8 | seventy five | Oil circulation | Resolver | B35 |
SRPM205M8XO132 | 380 | 132 | one hundred and five | 12000 | 96.five | S1 | H/F | IP67 | eight | 80 | Oil circulation | Resolver | B35 |
SRPM205M8XO160 | 380 | 160 | 127.3 | 12000 | 96.5 | S1 | H/F | IP67 | 8 | 87 | Oil circulation | Resolver | B35 |
SRPM205M8XO185 | 380 | 185 | 147.two | 12000 | 96.five | S1 | H/F | IP67 | 8 | ninety five | Oil circulation | Resolver | B35 |
FAQ
1. Can performanent magnet synchronous motor be employed as generator?
No. Everlasting magnet synchronous motor is absolutely distinct from generator. It is only ac motor that outputs pace and torque to generate electric gadgets, but not power source.
two. Why can not right use three period ac source voltage to commence permanent magnet synchronous motor?
Becuase rotor is with massive innertia, and magetic data files spins so rapidly that static rotor has no way to spin with magetic filed.
three. Any specific technical ask for on this motor’s VFD driver? And Do you have these kinds of driver?
Permanent magnet synchronous motor’s driver must be vector management VFD with unique interior application, this sort of as Siemens 6SE70 collection, Yakawa CR5 sequence, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 sequence, and many others.. Indeed, our MH300 sequence VFD matches with this motor.
4. Is there any protective steps to protect permanent magnet rotor from failure?
Yes, each and every permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization take a look at, linear demagnetization take a look at, etc. Its demagnetization index is inside two%. But if operating surroundings is serious oxiditive corrosion, kindly advise for greater safety level.
five. In which is this everlasting magnet synchronous motor normally utilized to?
This everlasting magnet synchronous motor is normally used to variable frequency velocity situation.